![]() ![]() ![]() The antenna for the communicator should be positioned to give as strong a cellular signal as possible. The communicator is mounted elsewhere, in an area where a strong cellular signal can be achieved. The DSC PCL-422 is typically mounted inside the same metal enclosure as the panel, usually on the side. Everything goes through the DSC PCL-422 in some manner. Nothing connects directly between the communicator and the panel. The DSC PCL-422 then connects with the panel using the included PC-Link Cable. The communicator and the DSC PCL-422 have six (6) wired connections in total. These are the NEO Panel, the communicator, and the DSC PCL-422 Remote Communicator Module. When installing a communicator for a DSC PowerSeries NEO, there are three (3) components to consider. An external power supply will use its own transformer and battery. The DSC HSM2300 can be used very well for this task. ![]() If you find that adding a communicator will push the system over the recommended load limit, then you can add an external power supply to provide additional power. For reference, the NEO can provide a maximum of 700mA of power, with DSC recommending that the load not exceed 650mA. Make sure your NEO System has enough available current to power the communicator, as well as all of the other connected devices for the system. During an alarm state, the communicator will draw up to 400mA of power from the panel. It will not use its own transformer or backup battery. Both represent a great option when upgrading a DSC PowerSeries NEO to use LTE.Īn external communicator for the NEO will draw power from the panel. Some of the most popular communicator options for the DSC PowerSeries NEO include the DSC TL880LEAT N AT&T LTE & IP Communicator and the DSC TL880LTVZ N Verizon LTE & IP Communicator. The IP portion is technically optional, but there isn't really any disadvantage to setting up internet connectivity to serve as an additional communication path. Per requirements, the cellular portion of the communicator must be activated and registered. These dual-path communicators use LTE cellular connectivity and IP connectivity through a wired ethernet cable to communicate with the servers. Pc interface for dsc alarm panel series#The system has a series of dual-path communicators available. The DSC PowerSeries NEO needs an external communicator for alarm monitoring service and connectivity with. You can activate the communicator for monitoring once it is wired. You should have the system powered down during the installation. You can add an external communicator to a DSC PowerSeries NEO by completing all the connections between the panel, the communicator, and the PCL-422 module. Adding an External Communicator to a DSC PowerSeries NEO ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |